SPD
High temperature data loggers management software for computers. It allows to start the devices setting the start delay, mission and duration
|
SterilDisk, S-Disk J, P-Micro, S-Micro, S-Radio, S-MicroW, L-Disk management software, supports DiskInterface HS Mini, DiskInterface HS, Universal Multibay and USB Radio Receiver. Downloadable from Tecnosoft website and included with the interfaces.
It's easy to use, intuitive and full of options. It allows to start the devices setting the start delay, mission duration, notes. After download data are then displayed on graph, with zoom function, and table, exportable in Excel. A multi-graph function is also present to display many curves on a single graph.
It is possible to put two vertical markers (lines) to highlight a particular area of the process, giving a name to the markers too: for example, it is possible to select the begin and the end of the process, or a particular phase of it, calculating the lethality value for that portion only.
The software calculates the lethality value (F0, PU, A0 etc.) of the process to evaluate the level of sterilisation or pasteurisation. In the configuration window it is possible to set the parameters, such as Z and reference temperature, for the lethality calcualtion according to the process you want to monitor. The software, moreover, allows to print complete reports with graph, data table, device serial number, and other notes added by the user. It is also possible to see the battery status of the connected device.
The software allows to print complete reports with graph, table, mission data, serial numbero of the device and notes. It is also possible to check battery status on screen.
A special feature gives the possibility to set a stop time for the mission: you can program the logger to automatically stop acquisitions after a certain period expressed in seconds, minutes, hours or days.
The SPD software supports the wireless data logger for pasteurisation and sterilisation too, P-Radio and S-Radio. Through the USB Radio Receiver you will be able to receive data in real time from your process. You will see the data one after another, you will be able to assign an alarm profile (on lethality values and temeprature values to be reached) and you can choose up to 4 sensors (that can be selected any time) to display a graph both for the temperature and the progressive lethality curve. It is possible to ask to calcualte lethality only for certain curves and exclude the other sensors from the statistics.
|
· SterilDisk / P-Micro / S-Micro / S-Disk J / S-MicroW / L-Disk / S-Radio
· DiskInterface HS Mini / DiskInterface HS / Universal Multibay
- S-Radio temperature data logger
- DiskInterface HS or Universal Multibay
- USB Radio Receiver or Ethernet Receiver (for Process Monitor Pro software only)
- SPD software, TS Manager software (compatible with the FDA 21 CFR Part 11 regulation) or Process Monitor software
Specifications
Operating systems
|
Windows 7, 8, 10 (32, 64 bit)
|
Operating systems
|
Windows XP, Vista, 7, 8, 10 (32, 64 bit)
|
Data loggers supported
|
SterilDisk, P-Micro, S-Micro, S-Disk J, S-MicroW, L-Disk, S-Radio, PasteurDisk, P-Radio
|
Data management
|
Missions sorted by starting date and logger serial number
|
Data display
|
Graph (with zoom) and table (exportable into Excel), markers for process start and end, printed report of all the data, Multi graph
|
Customizable parameters
|
Acquisition step, mission duration, notes, Z and reference temperature value for lethality calculation (F0, PU, A0 etc.)
|
Calculated parameters
|
Lethality (F0, PU. A0 etc.)
|
Alarms
|
Local (acoustic and/or visual) on PC (for P-Radio, S-Radio only)
|
Accessories
|
DiskInterface HS Mini, DiskInterface HS, Universal Multibay, USB Radio Receiver
|
Languages
|
English, Italian, German, French, Spanish, Japanese
|
|
Download
DiskInterface HS, DiskInterface HS Mini - USB drivers Windows 8 / 10
|
Multibay - USB drivers Windows Xp / Vista / 7
|
Multibay - USB drivers Windows 8 / 10
|
DiskInterface (old model) - USB driver Windows XP / Vista / 7 / 8 / 10
|
|
HumiPressureDisk
PressureDisk, RHTemp, Pirani management software with starting and setting mission's parameters
|
PressureDisk, RHTemp, Pirani Vacuum Logger management software, supports DiskInterface HS. Downloadable from Tecnosoft website and included with the interfaces.
|
- loggers starting, setting mission's parameters (acquisition step etc.)
- loggers data downloading
- graph display of the recorded acquisitions
- export data to excel file
- PressureDisk / RHTemp / Pirani Vacuum Logger
- DiskInterface HS
Specifications
Operating systems
|
Windows 7, 8, 10 (32, 64 bit)
|
Data loggers supported
|
PressureDisk, RHTemp, Pirani Vacuum Logger
|
Data management
|
Every mission is saved in a single file
|
Data display
|
Graph (with zoom), data exported to Excel
|
Customizable parameters
|
Acquisition step
|
Accessories
|
DiskInterface HS
|
Languages
|
English, Italian, German, French, Spanish, Japanese
|
Download
DiskInterface HS, DiskInterface HS Mini - USB drivers Windows XP / Vista / 7
|
DiskInterface HS, DiskInterface HS Mini - USB drivers Windows 8 / 10
|
HumiPressureDisk 1.1.2.0 - Complete software (USB drivers included)
|
DiskInterface (old model) - USB driver Windows XP / Vista / 7 / 8 / 10
|
|
|
TS Manager
Temperature, humidity, pressure loggers for high temperature management software, that meets all requirements of FDA 21 CFR Part 11 regulations
|
SterilDisk, S-Micro, S-Radio, S-MicroW, RHTemp, PressureDisk, Pirani Vacuum Logger, TempStick, HumiStick management software, supports DiskInterface HS Mini, DiskInterface HS, Universal Multibay, TecnoStick Interface. Downloadable from Tecnosoft website and works with its hardware protection key only.
The software meets all requirements of FDA 21 CFR Part 11, GAMP5, Annex 11 regulations and presents some peculiar features meeting some requirements of particular applications. It is dedicated to process and instrument, particularly autoclaves, validation.
|
- Data in the devices not editable
- Data in software not editable and encryptable
- Access for each user throgh login and password
- Client/server setup and shared database
- Multi-user access
- Multi-level users, with different functions for each one
- Customers and validated Instruments database for validators activity
- Logbook: recording, not editable, of all carried out operations
- Data analysis through pre-set or customizable parametres
- Possibility of pre and post mission comments
- Vasualization in graph, with zoom, and table
- Multi graph analysis
- Graph divided into Sections with analysis and statistics for each section
- Synchronized data table with statistics for each acquisition: maximum, minimum, average, maximum-minimum, maximum-maverage, average-minimum
- Theoretical temperature calculation based on pressure in satured steam environment
- Print of customizable reports
- Data and reports export in HTML and XLS (MS Excel) format
- SterilDisk / S-Micro / S-MicroW / S-Radio / RHTemp / PressureDisk / Pirani Vacuum Logger
- DiskInterface HS Mini / DiskInterface HS / Universal Multibay
- TempStick / HumiStick
- TecnoStick Interface
Specifications
Operating systems
|
Windows 7, 8, 10 (32, 64 bit)
|
Regulation compatibility
|
FDA 21 CFR Part 11
|
Data loggers supported
|
SterilDisk, P-Micro, S-Micro, S-Disk J, S-MicroW, L-Disk, RHTemp, PressureDisk, S-Radio, Pirani acuum Logger, TempStick, HumiStick
|
Data management
|
Client/server database with single missions, groups, customers, instruments, devices, programming profiles
|
Data display
|
Client/server database with single missions, groups, customers, instruments, devices, programming profiles
|
Customizable parameters
|
Acquisition step, mission duration, analyisi type (lethality with Z and reference temperature values setting, Overkilling for validation)
|
Calculated parameters
|
Lethality (F0, PU. A0 etc.)
|
Accessories
|
DiskInterface HS Mini, DiskInterface HS, Multibay universale, TecnoStick Interface
|
Languages
|
Italian, English, German
|
|
Ordering codes
|